  "schema_version": "volmax.evidence_manifest.v0.1",
  "case_id": "sandia",
  "asset_id": "SNL_18650_NMC_25C_0-100_0.5-2C_a",
  "upstream_pins": [
    {
      "repo_name": "VolMax-Studio/bess-evidence-lab-mvp",
      "repo_path": "upstream/bess-evidence-lab-mvp",
      "pinned_commit": "2dd708e",
      "entrypoint": "verifier/verify.py",
      "entrypoint_sha256": "ea1f682429b8f1126509edc936d7bdd3948034ed59e922a67eb0ebbe2873139d"
    }
  ],
  "input_files": [
    {
      "role": "raw_cycling_csv",
      "path": "data/raw/cell.csv",
      "sha256": "e34c2a5ee32c9922e2def6f387d9ba553c27d07ae5a99452f3b15640b339bfc6",
      "rows": 660
    },
    {
      "role": "source_metadata",
      "path": "data/SOURCE.json",
      "sha256": "f51ebbb0c4e708679e4cf3697b11c764f97499a3f3c80b71e29cdea4e55d4f6c"
    },
    {
      "role": "claim_definition",
      "path": "claim/claim.json",
      "sha256": "0a30a4e80fe185e952627dc1db3cc2a62c8c812cea4c001dc694b32dae86a116"
    }
  ],
  "calculation_sha256": "cfc93403e4d2a29f08603b0a56155e2279c34963debe7ea41b64d960c1a64f33",
  "calculation_method_and_version": "bess-evidence-lab-mvp/verifier/verify.py (2dd708e) + sandia_adapter.py v0.1.0",
  "reproduction_command": "python -m dossier_engine.cli build --case sandia --out-dir output",
  "limitations": [
    "Single laboratory cylindrical 18650 cell (LG Chem 18650HG2, 3.0 Ah nominal); cannot be scaled directly to pack or plant-level BESS capacity or AC RTE.",
    "Cycle-4 anomalous double-capacity artifact detected: 5.767 Ah discharge (5.796 Ah charge, 1.998-4.200 V); similar ~132-cycle-interval artifacts appear at cycles [4, 137, 269, 401, 533].",
    "Cycle sequence spans [1, 661] across 660 rows: missing cycle indices [133], and 5 rest/pause rows [132, 265, 397, 529, 661] record 0.0 Ah / 0.0 A.",
    "No DCIR / HPPC internal resistance measurements or per-second cell temperature time-series exist in cell.csv.",
    "ML RUL / conformal UQ models (Battery_Health_Portfolio, volmax-uq-bess-audit) are excluded because they are trained on LFP/LCO datasets and lack OOD exchangeability or NMC cell calibration."
  ],
  "emitted_artifacts": [
    {
      "role": "dossier_json",
      "path": "sandia_dossier.json",
      "sha256": "7a50af8212a83107e5d376b5f5681fa6adcda3890ec71ab06857dc39dbf9b59f"
    },
    {
      "role": "dossier_html",
      "path": "sandia_dossier.html",
      "sha256": "b3d33ae39ab4ecb0e57d96fd7bacac6c1731c249d95d05c3a417520838cda826"
    },
    {
      "role": "chart_png",
      "path": "sandia_capacity_retention.png",
      "sha256": "739200633e2034138987d8319fab4dfbebc21958b04e3be1288f5fed57d38e14"
    }
  ]
}